ifm efector DataLine IO-Link Master
IO-Link Master with IO-Link and EtherNet fieldbus interface, 4 or 8 input/output ports, secondary IIoT port, and IP65, IP66, IP67, IP69K rating.
Effective March 30th, 2026, ifm effector has added an 8% surcharge to this product. The surcharge will appear as a separate line item on the order.
- By ifm efector
Overview
Features
- Operating voltage:
- Standard: 20 to 30VDC
- IP69K model: 20 to 28VDC
- 300 to 3900mA current consumption
- IO-Link Master Interface:
- IO-Link revision 1.1
- COM1 (4,8 kBaud); COM2 (38,4 kBaud); COM3 (230,4 kBaud)
- Ethernet IIOT port with MQTT JSON protocol
- Fieldbus interfaces:
- PROFINET
- EtherNet/IP
- EtherCAT
- Modbus TCP
- POWERLINK
- 4 or 8 configurable IO-Link class A ports:
- 8 or 16 digital inputs
- 4 or 8 digital outputs
- Short-circuit protected inputs and outputs
- Electrical connections:
- Ethernet: D-coded M12 connector with 4 contacts
- IO-Link: A-coded M12 connector with 4 contacts
- Voltage supply: A-coded M12 connector with 4 contacts
- IP65, IP66, IP67 protection rating
- IP69K with hygienic models
This product is an accessory for the following products:
Description
The ifm efector DataLine IO-Link Master enables the connection of up to eight IO-Link devices, including sensors, valves, or binary input/output modules. The DataLine series IO-Link master features an integrated fieldbus interface with daisy-chain function and IO-Link and Ethernet communication interfaces. This model also has a secondary IIoT port for direct data transfer to high-level software systems without a PLC, separating the automation and IT networks.
The DataLine IO-Link master uses IO-Link and Ethernet communication interfaces to reliably transmit machine data, process parameters, and diagnostic data to the controller. All models have an Ethernet IIoT port with MQTT/JSON protocol. Some models may be configured with an additional Ethernet interface that uses EtherNet/IP, PROFINET, EtherNet/IP, EtherCAT, Modbus TCP, or POWERLINK protocols.
The DataLine IO-Link Master offers excellent electromagnetic stability, a wide temperature range, a high protection rating, and a robust housing, making it suitable for harsh industrial environments and the food industry. All models feature A-coded M12 IO-Link and voltage connections. The industrial model has a D-coded M12 Ethernet electrical connection with FKM seals; meanwhile, the hygienic model has an Ethernet connection with EPDM seals.
The IP69K DataLine masters feature 316 stainless steel hardware to withstand the harsh environment. The housing of these hygienic models is convex, providing better cleaning angles and mounting offsets. This prevents particles and bacteria from becoming trapped during cleaning processes.
Documents
Spec Sheets
- ifm efector AL1300 DataLine IO-Link Master Datasheet and Manual PDF (1.9 MB)
- ifm efector AL1301 DataLine IO-Link Master Datasheet and Manual PDF (1.8 MB)
- ifm efector AL1302 DataLine IO-Link Master Datasheet and Manual PDF (2.0 MB)
- ifm efector AL1303 DataLine IO-Link Master Datasheet and Manual PDF (2.0 MB)
- ifm efector AL1304 DataLine IO-Link Master Datasheet and Manual PDF (2.1 MB)
- ifm efector AL1305 DataLine IO-Link Master Datasheet and Manual PDF (2.1 MB)
- ifm efector AL1306 DataLine IO-Link Master Datasheet and Manual PDF (2.3 MB)
- ifm efector AL1307 DataLine IO-Link Master Datasheet and Manual PDF (2.3 MB)
- ifm efector AL1320 DataLine IO-Link Master Datasheet and Manual PDF (2.3 MB)
- ifm efector AL1321 DataLine IO-Link Master Datasheet and Manual PDF (2.3 MB)
- ifm efector AL1322 DataLine IO-Link Master Datasheet and Manual PDF (2.5 MB)
- ifm efector AL1323 DataLine IO-Link Master Datasheet and Manual PDF (2.5 MB)
- ifm efector AL1324 DataLine IO-Link Master Datasheet and Manual PDF (2.3 MB)
- ifm efector AL1325 DataLine IO-Link Master Datasheet and Manual PDF (2.3 MB)
- ifm efector AL1326 DataLine IO-Link Master Datasheet and Manual PDF (2.5 MB)
- ifm efector AL1327 DataLine IO-Link Master Datasheet and Manual PDF (2.5 MB)
- ifm efector AL1330 DataLine IO-Link Master Datasheet and Manual PDF (1.9 MB)
- ifm efector AL1331 DataLine IO-Link Master Datasheet and Manual PDF (1.9 MB)
- ifm efector AL1332 DataLine IO-Link Master Datasheet and Manual PDF (2.1 MB)
- ifm efector AL1333 DataLine IO-Link Master Datasheet and Manual PDF (2.1 MB)
- ifm efector AL1336 DataLine IO-Link Master Datasheet PDF (824 KB)
- ifm efector AL1337 DataLine IO-Link Master Datasheet PDF (828 KB)
- ifm efector AL1340 DataLine IO-Link Master Datasheet and Manual PDF (2.1 MB)
- ifm efector AL1341 DataLine IO-Link Master Datasheet and Manual PDF (2.1 MB)
- ifm efector AL1342 DataLine IO-Link Master Datasheet and Manual PDF (2.3 MB)
- ifm efector AL1343 DataLine IO-Link Master Datasheet and Manual PDF (2.3 MB)
- ifm efector AL1350 DataLine IO-Link Master Datasheet and Manual PDF (1.6 MB)
- ifm efector AL1351 DataLine IO-Link Master Datasheet and Manual PDF (1.6 MB)
- ifm efector AL1352 DataLine IO-Link Master Datasheet and Manual PDF (1.9 MB)
- ifm efector AL1353 DataLine IO-Link Master Datasheet and Manual PDF (1.9 MB)
- ifm efector AL1370 DataLine IO-Link Master Datasheet and Manual PDF (2.3 MB)
- ifm efector AL1371 DataLine IO-Link Master Datasheet and Manual PDF (2.3 MB)
- ifm efector AL1372 DataLine IO-Link Master Datasheet and Manual PDF (2.6 MB)
- ifm efector AL1373 DataLine IO-Link Master Datasheet and Manual PDF (2.6 MB)
Links
Need Help? Call an engineer at 1-800-884-4967
We're open 8:00 am to 5:00 pm ET