Laurel Laureate AC Voltage & Current Panel Meter
Starting at $270.00

Some models in stock. View available part numbers.

Need Help? Call 1-800-884-4967
Mo-Th 8am to 5:30pm. Fr 8am to 5pm ET

Features

  • 0.2, 2, 20, 200 & 600V AC or AC+DC voltage ranges
  • 2, 20, 200 mA & 5A AC or AC+DC current ranges
  • True AC RMS measurement with crest factor of 3.0 at full scale
  • Fast response: reading in 0-16.7 ms after each signal cycle to full accuracy
  • Accurate to 0.03% of full scale, 0.1% to 100% of FS, 10 Hz to 10 kHz
  • Universal 85-264 VAC / 90-300 VDC or 10-48 VDC / 12-32 VAC power
  • Wide choice of options:
  • 2 or 4 relays, mechanical or solid state (isolated)
  • Analog output, 4-20 mA, 0-10V, or -10V to +10V (isolated)
  • Serial data I/O: Ethernet, USB, RS485, RS232 (isolated)
  • Custom curve linearization, rate from consecutive readings

The Laurel Laureate™ is a 60,000 count True RMS digital panel meter with exceptional performance at half the price of a bench top meter. It can measure true RMS voltage or current of AC signals where there is considerable distortion of the waveform, such as rectifier outputs or waveforms chopped by an SCR, TRIAC or transistor circuit.

The Laurel Laureate™ has a basic accuracy to 0.03% of full scale for signals from DC to 10 kHz and signal amplitudes down to 0.1% of full scale. The crest factor (Vp / Vrms) is 3.0 at full-scale Vrms of 20,000 counts and a Vp of 60,000 counts. The meter starts to flash overrange at 132% of full scale Vrms , at which point the available crest factor is 60,000 / 26,400 = 2.27. Meaningful readings with rated peak and valley readings that occur at the nominal rate of 50/60 Hz. resolution continue to be obtained up to 212% of full scale Vrms (42,433 counts) for sinusoidal signals, at which point the available crest factor is 1.414. For safety reasons, the maximum RMS input signal should never exceed 600V or 5A. ETL certification is for a maximum voltage of 300 Vrms.

True RMS readings in 0-16 ms after completion of one input signal cycle allow the Laureate to detect anomalies before they become expensive problems. Fast on/off control and alarm can be achieved with optional dual or quad relays, either contact or solid state. The meter can also capture

AC or DC coupling is jumper selectable on the signal conditioner board. AC coupling accommodates signals from 10 Hz to 10 kHz and is suitable for applications such as measuring AC ripple on a DC power supply. DC coupling accommodates signals from 0 to 10 kHz. Multiple integral cycles are averaged for signals above 50/60 Hz. A single cycle is captured for signals from 3 Hz to 50/60 Hz. Below 3 Hz and at DC, the capture rate is 3/sec.

The Laurel Laureate™ AC voltage & current panel meter is designed for system use. Optional plug-in boards for communications and control include Ethernet and other serial communication boards, dual or quad relay boards, and an isolated analog output board. Laureates may be powered from 85-264 Vac or optionally from 12-32 Vac or 10-48 Vdc. The display is available with red or green LEDs. The 1/8 DIN case meets NEMA 4X (IP65) specifications from the front when panel mounted. Any setup functions and front panel keys can be locked out for simplified usage and security. All power and signal connections are via UL / VDE / CSA rated screw clamp plugs.

Cables

Laurel CBL01 RS232 Cable
RJ11 to DB9 cable connects RS232 port of PC to RS232 port of meter
$19.00
Laurel CBL02 USB-to-RS232 Adapter Cable
Connects the USB port of a PC to a Laureate meter with an RS232 option board
$39.00
Laurel CBL03 RS485 Data Cable
Straight through 6-wire data cable allows dual RJ11 jacks of the RS485 option board of Laureate meters
$8.00
Laurel CBL05 USB Cable
A-to-B USB cable connects the USB port of a PC to the USB port of a Laureate meter
$15.00
Laurel CBL06 USB-to-RS485 Adapter Cable
Connects the USB port of a PC to a Laureate meter with the RS485 option board with dual RJ11 jacks
$39.00

Protection

Laurel IPC Splash-Proof Cover
Protects 1/8 DIN instruments to NEMA-4 / IP67 from front
$40.00
Laurel BOX Enclosure
Wall mount polycarbonate enclosure sealed to NEMA 4X with optional slash-proof cover
$140.00
Part Number Price Available
L20014RMA2
Show Configuration
Base Price
$270.00
Model
Standard with red LED display
Power Supply
Isolated 85-264 VAC or 90-300 VDC
Relay Output
None
Analog Output
Isolated 4-20 mA, 0-20 mA, 0-10 V, -10 to 10V (+$90.00)
Digital Interface
RS485 Modbus (dual RJ45 connectors) (+$90.00)
Signal Input
20.000 mA
Reconfigure
$450.00 1

Interested in Other Part Numbers?