Features

  • Milliamp, Voltage, Frequency, Thermocouples, RTDs, Check Continuity
  • Troubleshoot loop & wiring problems
  • Checkout flow and vibration systems
  • Calibrate directly in temperature (°C & °F)
  • Use it as a milliamp and voltage calibrator
  • Sources and reads type Types J, K, T, E, R, S, B, N, G, C, D, L (J DIN), U (T DIN) and P (Platinel II) thermocouples
  • Sources and reads Pt 100 Ohm (3850, 3902, 3916, 3926) & 1000 Ohm (3850) Copper 10 & 50 Ohm, Nickel 100 and 120 Ohm RTDs
  • Technician friendly operation
  • Intuitive EZ-DIAL Double Click Menu makes setup easy
  • Easy to read backlit LCD display
  • Quickly set any three outputs plus automatic stepping & ramping

The Practical Instruments Electronics (PIE) PIECAL 820 process calibrator packs the power of six single function calibrators into one surprisingly small package. The perfect complement to any technician's toolbox, the PIECAL 820 combines advanced features, ease of use, accuracy, signal compatibility and compact size to make it the best value multifunction calibrator on the market today.

The PIECAL 820 process calibrator combines all milliamp loop functions and sources and reads DC Volts and millivolts, 14 thermocouple types, 9 RTD curves, ohms and process frequency signals. For troubleshooting connections it has a continuity tester with tone. All ranges have auto storing MIN/MAX readings and three output set points for fast calibration of zero, midpoint and span. Advanced features include automatic detection of 2, 3 and 4 wire RTDs plus configurable automatic stepping and ramping. A LED flashes green for frequency sync and lights up red for signal overload and invalid signal conditions.

The technician friendly PIECAL 820 is all about ease of use. An intuitive EZ-DIAL Double Click Menu makes it simpler to setup than larger calibrators with their complicated button filled panels and confusing menus. Use the PIECAL 820 right out of the box instead of wasting time learning to use more complex calibrators. The toolbox tough design includes a backlit display for use in dark environments and protective rubber boot with built in stand. NIST Calibration Certificate is included at no extra cost.

The PIECAL 820 multifunction process calibrator ships complete with:

  • Test Leads (3' long with retractable shield banana plug & alligator clips)
  • RTD Wire Kit (2 Red & 2 Black Leads with Retractable Shield Banana Plugs & Spade Lugs)
  • Protective Rubber Boot
  • Certificate of Calibration
  • Carrying Case
  • Four "AA" Alkaline batteries
PIECAL 820 Multifunction Calibrator Specifications:
Read mA
Ranges and Resolution 0.00 to 24.00 mA or -25.0 to 125.0% of 4-20 mA
Accuracy ≤ ± (0.03 % of Full Scale)
Voltage burden ≤ 2V at 24 mA
Overload/Current Limit Protection 25 mA nominal
Source mA / Power & Measure Two Wire Transmitters
Ranges and Resolution 0.00 to 24.00 mA or -25.0 to 125.0% of 4-20 mA
Accuracy ≤ ± (0.03 % of Full Scale)
Noise ≤ ± ½ Least Significant Digit
Temperature Effect ≤ ± 0.01 %/°C of Full Scale
Loop Compliance Voltage ≥ 24 DCV @ 20.00mA
Loop Drive Capability 1200 Ω at 20 mA for 15 hours nominal
950 Ω with Hart Resistor enabled
mA 2-Wire Transmitter Simulation
Accuracy Same as Source/Power & Measure
Voltage burden ≤ 2V at 20 mA
Overload/Current Limit Protection 24 mA nominal
Loop Voltage Limits 2 to 60 VDC (fuse-less protected from reverse polarity connections)
Voltage Read
Range and Resolution -10.00 to 110.00 mV, ±10.25 V, ±60.0 VDC
Accuracy ≤ ± 0.03 % of Full Scale
Temperature Effect ≤ ± 100 ppm/°C of Full Scale
Input Resistance ≥ 2 MΩ
Source VDC
Ranges and Resolution -10.00 to 110.00 mV, ±10.25 V, ±60.0 VDC
Accuracy ≤ ± (0.03 % of Full Scale)
Noise ≤ ± ½ Least Significant Digit
Temperature Effect ≤ ± 0.01 %/°C of Full Scale
Source Current ≥ 24 mA
Sink Current > 16 mA
Output Impedance < 0.3 Ohms
Short Circuit Duration Infinite
Thermocouple Source
Accuracy ±(0.03% of Full Scale) [Note: Full Scale is 110.0 mV]
Cold Junction Compensation ± 0.36°F (±0.2 °C)
Output Impedance < 0.3 Ohms
Source Current > 20 mA (drives 80 mV into 10 Ohms)
Noise ≤ 4 microvolts p-p for frequencies of 10 Hz or below
Thermocouple Read
Accuracy & Cold Junction Compensation Same as Thermocouple Source
Input Impedance > 1 Megohms
Open TC Threshold; Pulse 10K Ohms nominal ; < 10 μamp pulse for 300 milliseconds
RTD, OHMS and Continuity Read
Resistance Ranges 0.00 to 410.00, 0.0 to 4001.0 Ohms
Accuracy ±(0.03% of Full Scale + 0.075 Ohms)
Excitation Current 0.5 mA nominal
Continuity Beeps from 0.0 to 10.0 Ohms
RTD and Ohms Source
Accuracy Up to ±(0.03% of Full Scale + 0.075 Ohms)
Resistance Ranges 0.00 to 410.00, 0.0 to 4001.0 Ohms
Allowable Excitation Current Range < 410 Ohms: 10.2 mA max; steady or pulsed/intermittent
410 to 4001 Ohms: 1 mA max; steady or pulsed/intermittent
Pulsed Excitation Current Compatibility DC to 0.01 second pulse width
Frequency Source
Ranges 1 to 2000 CPM, 0.01 to 999.99 Hz, 0.1 to 9999.9 Hz, 0.0001 to 9.9999 kHz, 0.001 to 20.000 kHz
Accuracy ±(0.03% of Full Scale)
Output Waveform Square Wave, Zero Crossing -1.0 to +5 V peak-to-peak
Risetime (10 to 90% of amplitude) < 10 microseconds
Output Impedance < 0.3 Ohm
Source Current > 1 mA rms at 20 kHz
Short Circuit Duration Infinite
Optical Coupling Green LED (HZ SYNC) flashes at output frequency
Frequency Read
Ranges & Accuracy Same as Frequency Source
Accuracy ±(0.03% of Full Scale)
Trigger Level 1 V rms, dc coupled
Input Impedance > 1 Meg Ohm + 60 pF

Batteries/Chargers

PIE Ni-MH Batteries and Charger
Ni-MH 1 hour charger with 4 Ni-MH AA batteries
$80.00

Accessories

Please consider these optional accessories.

PIE RTD Wire Kit
2 red and 2 black leads with retractable shield banana plugs and spade lugs
$55.00
PIE Certified Test Data for Calibrators and Simulators
$100.00
PIE 020-0236 Magnet and Hanging Strap
Hang your PIE calibrator from racks, cabinets, and from pipes
$19.00