AOI Series 2000 Oxygen Analyzer
Starting at $2,900.00

Not in stock. Usually ships in 3-4 weeks [?]

Need Help? Call a Calibration Engineer 1-800-884-4967

We're open Mo-Th 8am to 5:30pm. Fr 8am to 5pm ET

Features

  • Single-range measurement options
    • 0-5, 0-10, 0-25, or 0-100 percent
  • Optional three-range measurements
    • 0-1/10/25 percent
    • 0-5/10/25 percent
    • 0-10/25/100 percent
  • ±1% of full scale accuracy
  • 90% of full scale in less than 20 seconds response time
  • 4-20 mADC and 0-20 VDC standard outputs
  • 40 to 104°F (5 to 40°C) operating temperature range
  • Factory calibration
  • 0.4in (10.2mm) high, 4-1/2-digit LCD
  • 2-year sensor and electronics warranty
  • NEMA 1 (IP 30) standard configuration
  • Optional watertight enclosures rated NEMA 4X (IP 66)
  • Optional explosion-proof enclosures rated NEMA 7
    • Class I, Groups B, C, D, Div 1
    • Class II, Groups E, F, G
    • Class III

The AOI Series 2000 oxygen analyzer is a microprocessor-controlled monitor that can be supplied with oxygen measuring ranges from 0-1% to 0-100%, either in a single range or optional three-range configuration. All three-range analyzers feature autoranging. The analyzer has built-in visual and audible alarms. The front panel contains five switches that provide access to the instrument's settings. Each analyzer is equipped with three oxygen alarm relays and one status alarm relay, which are user-configurable for fail-safe operation.

The Series 2000 features an extended-life oxygen sensor with an enhanced electrolyte system. For applications where carbon dioxide is present in the sample gas, the system retards passivation of the sensor anode by allowing the products of oxidation to dissolve in the electrolyte. The sensor is renewed continuously, resulting in an increase in sensor life even if exposed to 100% carbon dioxide. The enhanced mechanical design of the sensor ensures longer life, and virtually eliminates leakage of electrolyte.

The monitor is available in a variety of optional mechanical configurations from watertight (NEMA 4) to explosion-proof (NEMA 7). The gas inlet and outlet connections on the sensor housing are quick-connect types. One-quarter inch stainless steel compression fittings are available upon request at no additional charge. The monitor can also be configured with an optional remote sensor that may be placed up to 1,000 feet (300 meters) from the electronics.

AOI SS-4TF-2 Sample Filter
High-capacity sample filter recommended for when particles are >5 microns, 316SS body and filter element with 1/4in compression fittings
$420.00
AOI FLM-QC-QC Flowmeter
One-piece acrylic flow meter without flow control adjustment, 1/4in quick connects on input and output
$180.00
AOI FLMC-QC-QC Flow Meter
One-piece acrylic flow meter with flow control adjustment, 1/4in quick connects on input and output
$200.00
AOI PR-100 Pressure Regulator
Aluminum body and stainless steel needle valve, maximum pressure input of 100psig (7.03kg/cm²)
$550.00
AOI PMP-24 Sample Pump
For use in applications with sample pressure from 12 to 14.9 psia (827 to 1027 mbar), 24 VDC
$470.00
AOI PMP-220 Sample Pump
For use in applications with sample pressure from 12 to 14.9 psia (827 to 1027 mbar), 220VAC
$470.00
AOI 2SEN Replacement Sensor
Replacement sensor for Series 2000 oxygen analyzer
$330.00
AOI NV-SS-2C-2C Flow Control Valve
Mounted on the sample inlet and made of stainless steel
$215.00
AOI AFM20 Coalescing Filter
Aluminum housing recommended for samples containing a very light mist and particles >30 microns
$360.00
AOI AFM-FE Filter Elements
Spare filter elements for the AFM20 coalescing filter
$45.00
AOI SS-FBX Spare Filter Elements
316 stainless steel filter elements for the SS-4TF-2 filter
$45.00
AOI PR-3000 Pressure Regulator
Stainless steel with a 3,000psig (211kg/cm²) inlet capacity and adjustable outlet pressure range of 0 to 5psig (0 to 0.35kg/cm²)
$1,090.00