Starting at $8,052.00

Usually ships in 4 weeks [?]

Need Help? Call 1-800-884-4967 8:00am to 5:30pm ET

Features

  • Net O2 range: variable 0-10% to 0-40%
  • Lengths from 18” (.9m) to 18’ (5.5m)
  • ANSI, DIN and special flanges (1.8m) (5.5m)
  • Flat-faced (snubber), hastelloy and ceramic diffusers
  • Advanced sensor diagnostics
  • Electronics mounted to probe or separate
  • Digital HART or FOUNDATION fieldbus communications
  • Fully field-repairable
  • Variable probe insertion option
  • Calibration: semi-automatic or automatic

The Rosemount Oxymitter 4000 In Situ Oxygen Transmitter was the world's first in situ, zirconium oxide-based oxygen transmitter for flue gas measurement. These oxygen measurements can be used in a control system or by a boiler operator to fine tune burner fuel/air ratios for maximum efficiency. Ideal for:

  • Boilers
  • Process heaters
  • Kilns
  • Reheat furnaces

Emerson Process Management is the leader in oxygen flue gas analyzer technology. Our in situ, zirconium oxide oxygen analyzers have long been established as industry standards. We've combined our expertise with the latest Rosemount transmitter technology to create a truly revolutionary package, the Oxymitter.

The Oxymitter integrates an oxygen probe and field electronics into a single, compact package. The probe inserts directly into a flue gas duct to measure oxygen in combustion processes. No sampling system is required.

A NEMA 4X, IP 66 Rosemount transmitter housing mounts directly to the probe and contains the transmitter's electronics, replacing common stand-alone field electronics. This integrated design minimizes the costs of installing separate probe cable, conduit and electronics.

The Oxymitter electronics also require 95% less power to operate. So, its components last longer. Traditional architecture with remote-mounted electronics is also offered.

The HART protocol provides a link into Emerson Process Management's PlantWeb field-based architecture. Instrument technicians can interface with the Oxymitter from the control room or any location where the transmitter's signal wires terminate. Service diagnostics and calibrations can be performed remotely with a HART hand-held communicator or a personal computer equipped with AMS.

The Oxymitter is fully field-repairable. The probe's design provides convenient access to internal probe components so technicians can service the unit in house. The cell and heater/thermocouple are fully field-replaceable. The Oxymitter contains no potentiometer adjustments or jumpers.

The Oxymitter In Situ Oxygen Transmitter operates at process temperatures up to 1300°F (700°C), providing a fast response with high accuracy and reliability. Available lengths from 18 inches to 18 feet.

Probes

Rosemount Analytical Quick Ship O2 Probes
6' or 18" Oxymitter O2 probes
$9,177.00
Rosemount Analytical Single Probe Autocal System
SPS 4001 Single Probe Autocal System - Single Board Design (not CE certified)
$2,295.00

Cables

Rosemount Analytical Signal Power Cables
20' to 200' length options, general purpose
$708.00

Accessories

Please consider these optional accessories.

Rosemount Analytical Bypass Packages Inconel 600
Bypass Packages Inconel 600 1050°C (1922°F), for use with general purpose oxymitter, WC or X-stream O2 probes
$5,633.00
Rosemount Analytical Intelligent Multiprobe Sequencers
Intelligent multiprobe sequencers (IMPS) will auto-calibrate up to 4 probes general purpose service only
$9,092.00
Rosemount Analytical Local Operator Interface
Gas Fluorescent Local Operator Interface (LOI) for Oxymitter, requires Glass Cover 08732-007-002
$1,194.00
Rosemount Analytical OxyBalance Display
Trending and averaging electronics, NEMA 4X enclosure option
$11,059.00
Rosemount Analytical Oxygen Test Gas Kit
$2,992.00
Rosemount Analytical Pressure Balancing System
Manual or auto calibration, cal gas line or N2 purge for process taps
$9,499.00
Rosemount Analytical 99CC Calibration Certificate
One certificate per lot at standard factory ranges only, includes the model, serial and/or tag numbers (does not include actual test data)
$106.00
Rosemount Analytical Electronic Calibration
Certificate for specific unit, includes model, serial and/or tag numbers, test standards, NIST report numbers, & the actual test data
$159.00
Rosemount Analytical Certificate of Origin
Original certificate of origin with chamber of commerce stamp
$264.00
Rosemount 1410 Wireless Gateway
Connects WirelessHART networks with host systems & data applications, offers network flexibility for remote indoor operations
$1,797.57
Rosemount 1420 Wireless Gateway
NEMA 4X gateway connects WirelessHART networks with host systems with the capacity for up to 100 devices
$4,574.15
Rosemount 775 Wireless THUM Adapter
Enables wireless capabilities for 2, 3, or 4-wire HART devices to remotely manage, monitor & gather data
$867.31

Spare Parts

Rosemount Analytical Oxymitter Probe Tube
15' or 18' ANSI Oxymitter Probe Tube
$13,732.00
Rosemount Analytical Heater/Strut Assembly
Heater/strut assembly: OXT4A, OXT5A 18", 3', 6', 9' or 12' length options
$1,701.00
Rosemount Analytical Cell Replacement Kit
Cell replacement kit; ANSI or DIN with 18", 3', 6', 9', or 12' lengths
$1,683.00

Applications

This product can be used in the following applications: