Overview

Features

  • 0.05Ω to 1500Ω resistance range
  • 0.5mA to 35.0A current range
  • Large elliptical clamp design
  • Smooth mating surfaces on the clamp head
  • Visual alarm
  • Noise filter function
  • Intelligent data hold function
  • Data storage of 2,000 records
  • Time- and date-stamped results
  • Opto-coupled IrDA-USB for data storage
  • CATIV 600V operation

Description

The Megger DET14C and DET24C clamp-on ground resistance testers set new standards in terms of access, performance, features, simplicity of operation and safety. The DET14C and DET24C are used to measure earth/ground resistance in multiple loop installations without disconnecting the ground.

Designed with flat core ends, these units prevent dirt build-up, ensuring measurement integrity and improved reliability over products with interlocking teeth. Other enhancements include safety to CATIV 600V, a built-in filter function for electrically noisy environments, time and date stamped stored test results and ultra long battery life. The DET14C logs up to 256 records. The DET24C logs up to 2,000 records and has an opto-coupled IrDA-USB interface to download data. Megger has taken what is now a standard test method and significantly improved its field applicability.

The DET14C and DET24C are designed to quickly measure ground electrode resistance in applications where this type of test method can be used and/or verify the integrity of ground connections. The goal of ground resistance testing is to ensure that the resistance ground electrode system is low enough to prevent or limit voltage rises caused by fault current, electrical surges, lightning strikes, etc.

Clamp-on ground testers work in applications where there is a loop resistance to measure with ground paths in the system (the more ground paths, the closer to the actual resistance). A utility pole ground system is a classic example of this type of application.

Typical end users include:

  • Power utilities
  • Electrical contractors/electricians
  • Specialist grounding contractors
  • Electrical testing companies
  • Telecommunications companies
  • Railroads
  • Mining companies

Typical testing applications for the Megger DET14C and DET24C Clamp-on Ground Resistance Testers:

  • Pole grounds
  • Service entrance/meter ground electrodes
  • Service panels
  • Pad mount transformer grounds
  • Transmission tower grounds - utlility ground cables
  • Telephone pedestals
  • Telephone cabinets
  • Lightning protection ground electrodes

The Megger DET14C and DET24C Clamp-on Ground Resistance Testers ship complete with:

  • Carrying case
  • Carrying strap (wrist loop)
  • User guide CD-ROM
  • Calibration check
  • Battery AA (Alkaline) (4 required)
  • USB IrDA dongle (DET24C only)
  • PowerDB Lite software (DET24C only)