Features

  • Compact industrial design
  • Simultaneous measures up to 6 gases
  • Field replaceable sensors
  • Measures O2, CO, CO2, NO, NOX, NO2, SO2 (cells sold separately)
  • Infrared module (NDIR) for CO2 measurement
  • 3.5in TFT color and backlit display
  • Direct and continuous/discontinuous measurement
  • RS485 digital data transfer

The MRU SWG-100 CEM Emission Monitoring System is designed for use in the harsh industrial environment of different combustion sites, where flue gas emissions must be continuously monitored. The SWG-100 CEM can be installed in outdoor or indoor locations. The analyzer system can be configured with different gas sampling probes and sampling lines to optimize the sample gas preparation.

The SWG-100 CEM is used in a variety of industrial applications including:

  • Small power plants, small gas turbines
  • Food industry steam boilers
  • Cogeneration heat and power engines (CHP)
  • Bio methane and methane boilers
  • Waste incinerators, ovens and kilns
  • Ethanol and palm oil plants and more
  • Industrial heaters and dryers
MRU 65419 O2 Module
O2 analysis, 0 to 25%, using long-life electrochemical cell
$769.00
MRU 65990 CO Electrochemical Cell Measurement
CO Electrochemical Cell Module, including CO sensor cutoff valve and air purging pump for sensor protection
$1,183.00
MRU 65989 NO Electrochemical Cell Measurement
NO electrochemical cell measurement, using long-life electrochemical cell, 0 to 1,000 ppm measuring range
$743.00
MRU 65974 NO2 Electrochemical Cell Module
NO2 electrochemical cell measurement, 0 to 200 measuring range, 1,000 ppm overload
$866.00
MRU 65991 SO2 Electrochemical Cell Measurement
SO2 Electrochemical Cell Module, 0 to 1,000 ppm measuring range, 4,000 ppm overload
$869.00
MRU 65684 CO2 NDIR Bench
CO2 analysis using a non-dispersive infrared sensor with 0 to 20% measuring range with an overload of 40%
$1,316.00
MRU 62592A / 62592C Gas Sampling Probe
Gas sampling probe model LD, for low dust with on tip sintered metal filter
$1,278.00
MRU 61558F / 61558S Gas Sampling Probe
Gas sampling probe model HD, for flue gas with flying ash dust
$2,508.00
MRU 61557F / 61557S Gas Sampling Probe
Gas sampling probe model HD, for flue gas with flying ash dust
$3,300.00
MRU 65713 Mounting Set
Mounting set for probe HD or HD-GW
$348.00
MRU Gas Sampling Tube
Gas sampling tube for insertion in the stack and mounting on probe HD or HD-GW
$215.00
MRU 65757 Electric Gas Cooler
Electric gas cooler (Peltier type)
$871.00
MRU 66029 RS485 to Profi-Bus converter
RS485 to Profi-Bus converter
$843.00
MRU 66030 RS485 to Ethernet converter
RS485 to Ethernet converter
$584.00
MRU 64962 Cable Set
Cable set for probe HD or HD‐GW
$16.00
MRU 64537 O2 Analysis
Paramagnetic cell, 0 to 25%
$8,492.00
MRU 65968 CO Electrochemical Cell Measurement
CO electrochemical cell measurement, 0 to 4,000 ppm measuring range, 20,000 ppm overload
$876.00
MRU 65179 I/O Module
I/O Module with 4chanel 4-20mA analog output and 2 alarm relays (fail-safe NO contacts)
$348.00
MRU 61883 VORTEC Air Cooling
VORTEC air cooling for analyzer cabinet using dry compressed air 0.5 m3/min
$2,455.00
MRU 65430 Analyzer External Control
Analyzer external control via 4x contacts (relays or open collector transistors)
$468.00