Starting at $2,012.06

Usually ships in 2-3 weeks [?]

Need Help? Call 1-800-884-4967 8:00am to 5:00pm ET

Features

  • Pressure ranges from 0-3 to 0-100 psi gauge
  • Accurate up to ±0.1% of calibrated span (combined effects of linearity, hysteresis, repeatability)
  • 3A compliant and designed for CIP/SIP systems
  • Proof Pressure: Up to 2 times URL (160,000 psi max.)
  • Burst Pressure: Up to 5 times URL (180,000 psi max.)
  • Zero balance: ±1% FSO
  • Compensated temperature range: 0 to 170°F
  • Operating temperature range: -20 to 300° F
  • Fast Thermal Response Time
  • 316L SST construction for applications involving aggressive fluids
  • Range of output options (mVdc, Vdc, mAdc, or HART)
  • Includes NIST traceable calibration certificate

The Tel-Tru P331 is a sanitary tank level transmitter for Anderson, Cherry Burrell, or King Gage receivers. It is 3A compliant and designed for CIP/SIP systems. The key feature of the sensing element is advanced temperature compensation methods, which not only improves performance over a wide temperature band, but greatly reduces CIP/SIP recovery times. The P331 is manufactured for reliability and stability in high humidity environments, and where direct sprays for wash-down purposes are present.

The P331 is available in ranges from 0-3 to 0-1000 psi and is accurate up to ±0.10% of calibrated span. The transmitter is configurable to allow customers to tailor the instrument to the exact needs of their application. The P331's construction of all 316L SST makes it an ideal choice for applications involving aggressive fluids.

Applications for the Tel-Tru P331 pressure transmitter:

  • Biotech
  • Cosmetics
  • Dairy
  • Food and beverage processing
  • Pharmaceutical