Overview

Features

  • AC/DC voltage up to 600 V
  • AC current up to 1000 A
  • Resistance, Frequency and temperature measurement
  • Data logging to 5400 points
  • Audible continuity
  • Auto power off
  • Automatic polarity
  • Low battery indication
  • Data hold
  • LCD display
  • Accommodates conductors up to 1.77"
  • Voltage overload protection up to 600 V AC/DC
  • CAT III 600 V safety rating

Description

The Amprobe ACD-16 PRO data logging clamp-on multimeter is the perfect system trouble-shooting tool. The Amprobe ACD-16 PRO provides a full range of measurements, enhanced with data logging capabilities to catch what the eye can't see. An optional PC interface kit is available to download measurement data for storage and analysis.

The Amprobe ACD-16 PRO data logging clamp-on multimeter measures AC/DC voltage up to 600 V, AC current up to 1000 A, resistance, frequency and temperature. The Amprobe ACD-16 can data log up to 5400 points of data. Other features include an audible continuity test, auto power off, automatic polarity detection, low battery indication, data hold and LCD display.

Amprobe ACD-16 PRO data logging clamp-on multimeters ship complete with:

  • Test leads w/set of alligator clips (MTL-90B)
  • Thermocouple (TPK-59)
  • Carrying case (SB-U)
  • Manual

Amprobe ACD-16 PRO Data Logging Clamp-on Multimeter Specifications

Feature Range Accuracy
AC Voltage
50 Hz/60 Hz 600.0 V ±(1.0% + 5 d)
45 Hz ~ 500 Hz 600.0 V 1.5% + 5d
CMRR: > 60 dB @ DC to 60 Hz, Rs=1kΩ
Input impedance: 2 MΩ, 30 pF nominal
True RMS models Crest Factor: < 2.3 : 1 at full scale & < 4.6: 1 at half scale
DC Voltage
  600.0 V ±(0.5% + 5 d)
NMRR: >50 dB @ 50/60 Hz
CMRR: >120 dB @ DC, 50/60 Hz, Rs=1kΩ
Input impedance: 2 MΩ, 30 pF nominal
Ohms
  999.9 Ω ±(1.0% + 6 d)
Open circuit voltage: 0.4 V DC typical
Audible threshold: between 10 Ω and 300 Ω
Response time: 250 µs
Frequency
5.00 Hz ~ 500.0 Hz ±(0.5% + 4 d)
Sensitivity (Sine RMS)
40 A range: >4 A
400 A range: >40 A
1000 A range: >400 A
600 V range: >30 V
Temperature
  -50°C ~ 300°C 2.0% + 3°C
  -58°F ~ 572°F 2.0% + 6°F
Add 3°C (or 6°F) to specified accuracy @ -20°C ~50°C (or @ -4°F ~ -58°F). Type K thermocouple range & accuracy not included
ACA Current (Clamp-on)
50 Hz / 60 Hz 40.00 A, 400.0 A, 1000 A 1.0% + 5d
45 Hz ~ 500 Hz 40.00 A, 400.0 A 2.0% + 5d
  1000 A 2.5% + 5d