GE Druck PTX/PDCR 1840 Level Pressure Sensors
Fully submersible, high performance sensors for measuring hydrostatic liquid levels
Availability
Call for availability
Features
- Manufactured by GE Druck
- Ranges from 0.75 mH2O to 600 mH2O
- Accuracy
- Standard Accuracy: ±0.10% full scale
- High Accuracy: ±0.06% full scale
- Output
- PDCR 1840: mV
- PTX 1840: 4-20 mA
- Fully welded 17.5 mm titanium construction
- Integral lightning surge arrestor (optional)
- Vented Hytrel 6108 cable (hydrocarbon resistant)
- ATEX Certified intrinsically safe
- 5 year anti corrosion warranty
Includes FREE
The GE Druck PTX/PDCR 1840 are fully submersible, high performance sensors for measuring hydrostatic liquid levels. Combining a high technology sensor, advanced signal conditioning and rugged construction, the PTX 1840 and PDCR 1840 provide an ideal long term solution for reliable, accurate and economical level measurements.
The GE Druck PTX/PDCR 1840 have a measurement range from 0.75 to 600 meters of water. The standard accuracy is ±0.10% full scale while higher accuracy options are available. The PTX 1840 includes 4-20 mA output and the PDCR 1840 includes mV output. The micro-machined silicon element is sealed within an all-titanium pressure module assembly, fully isolated from the pressure media. This is contained in a slimline, welded titanium body, terminated in an injection molded cable assembly. The vented Hytrel 6108 cable is hydrocarbon resistant, includes a Kevlar strain cord and is IP68 rated. An optional integral lightning surge arrestor is available with the PTX 1840.
The rugged construction and sophisticated design of the GE Druck PTX/PDCR 1840 level sensors make them ideal for potable water applications from ground water borehole to surface water level measurements in rivers, canals and reservoirs; waste water and remediation applications including monitoring of secondary and outflow sewage levels within certified hazardous areas and contaminated ground water levels in land fill sites; tank level applications from land based liquid storage vessels to on-board ship ballast tank monitoring within safe and certified hazardous areas; and sea water applications such as tide gauging, coastal flood protection and wave profiling.
Specifications for the GE Druck PTX 1840 and PDCR 1840 level sensors:
| Parameter | PTX 1840 (mA) | PDCR 1840 (mV) |
|---|---|---|
| Operating Pressure Ranges | 0.75 to 600 mH2O gauge and 3.5 to 600 mH2O absolute (or equivalent) | |
| Overpressure | 8x for ranges up to 1.5 mH2O 6x for ranges from 1.5 to 3.5 mH2O 4x for ranges above 3.5 mH2O (1400 mH2O maximum) |
|
| Pressure Containment | 10x for ranges up to 3.5 mH2O 6x for ranges above 3.5 mH2O (1400 mH2O maximum) 200 bar for absolute ranges |
|
| Excitation Voltage | 9 to 30 V; 9 to 28 V for IS version | 10 V at 5 mA nominal |
| Output Signal | 4 to 20 mA proportional, for zero to FS pressure | 25 mV for 0.75 mH2O 50 mV for 1.5 and 3.5 mH2O 100 mV for ranges 7 mH2O and above |
| Accuracy | Standard: ±0.1% FS High Accuracy: ±0.06% FS (±0.08% FS < 1 mH2O) |
|
| Zero Offset and Span Setting | Maximum: ±0.05 mA | Typical: ±1.5 mV Maximum: ±3 mV |
| Long Term Stability | ±0.1% FS typically per annum | |
| Compensated Temperature Range | -2 to 30°C | |
| Temperature Effects | ±0.3% FS Temperature Error Band (TEB) ≥ 3.5
mH2O ±0.6% FS TEB for ranges < 3.5 mH2O |
|
| Shock and Vibration | MIL-STD-810E, method 514.4. Category 10 min. Figure 514.4-16 | |
| Intrinsic Safety (optional) | ATEX: Certified (BAS 01 ATEX 1018X) for use with IS barrier systems to EEx ia IIC T4 (-40°C < Tamb < 80°C) for cable lengths up to 300 meters max | ATEX: Certified (BAS 02 ATEX 1250X) for use with IS barrier systems to EEx ia IIC T4 (80°C ambient) for cable lengths up to 29 meters |
| Pressure Connection | Radial holed M14 x 1.5 mm male thread fitted with protective acetyl nose cone | |
| Electrical Connection | Vented Hytrel® 6108 cable (hydrocarbon resistant) with integral Kevlar® strain relief cord rated to 54 kg load. Water ingress protection IP68 to 700 mH2O | |