Features

  • Part number ACD-16 TRMS-PRO
  • Manufactured by Amprobe
  • True RMS
  • AC/DC voltage to 600 V
  • AC current to 1000 A
  • Resistance, frequency and temperature measurement
  • Datalogs up to 5400 points
  • Data hold
  • Large, easy to read digital dislay
  • Accommodates conductors up to 45 mm
  • Audible continuity
  • Voltage overload protection up to 600 V

The Amprobe ACD-16 TRMS-PRO 1000A datalogging clamp-on multimeter is the perfect tool to troubleshoot an entire electrical system. The ACD-16 TRMS-PRO provides a full range of measurements, enhanced with datalogging capabilities, to catch what the eye can't see. The efficiency of the meter is doubled when used in conjunction with the optional PC interface kit. True RMS functionality enables accurate readings in noisy electrical environments.

Amprobe ACD-16 TRMS-PRO 1000A datalogging clamp-on multimeters ship complete with:

  • Carrying case
  • Type-K thermocouple
  • Test leads
  • Batteries
  • User manual
The Amprobe ACD-16 TRMS-PRO 1000A Datalogging Clamp-on Multimeter Specifications
Function Range Accuracy
AC voltage
50 Hz/60 Hz 600.0 V 1.0% + 5d
45 Hz ~ 500 Hz 600.0 V 1.0% + 5d
500 Hz ~ 3.1 kHz 9 600.0 V 2.5% + 5d
CMRR: >60 dB @ DC to 60 Hz, Rs=1kΩ  
Input Impedance: 2MΩ, 30 pF nominal  
True RMS models Crest Factor: < 2.3:1 at full scale & < 4.6 at half scale  
DC voltage
  600.0 V 0.5% + 5d
NMRR: >50 dB @ 50/60 Hz  
CMRR: >120 dB @ DC, 50/60 Hz, Rs=1kΩ  
Input Impedance: 2MΩ, 30 pF nominal  
Resistance
  999.9 Ω 1.0% + 6d
Open circuit voltage: 0.4 VDC typical  
Audible continuity tester
Audible threshold: between 10Ω and 300Ω  
Response time: 250 µs  
Frequency
  5.00 Hz ~ 500.0 Hz 0.5% + 4d
Sensitivity (Sine RMS)
40 A range: > 4A
400 A range: > 40A
1000 A range: > 400A
600 V range: > 30V
Temperature
  -50°C ~ 300°C 2.0% + 3°C 1
  -58°F ~ 572°F 2.0% + 6°F 1
1)Add 3°C (or 6°) to specified accuracy@-20°C ~-50°C (or @-4°F ~ -58°F) Type-K thermocouple range & accuracy not included
AC Current (Clamp-on)
50 Hz/60 Hz 40.00 A, 400.0 A, 1000 A 1.0% + 5d1)2)3)
45 Hz~500 Hz 40.00 A, 400.0 A 2.0% + 5d1)2)3)
  1000 A 2.5% + 5d1)2)3)
< 2.5:1 at full scale & < 5.0:1 at half scale for 40.00 A & 400.0 A ranges < 1.4:1 at full scale for 1000 A range
1) Add 8d to specified accuracy while reading is below 10% of range
2) Induced error from adjacent current-carrying conductor: < 0.06 A/A
3) Specified accuracy is for measurements made at the jaw center. When the conductor is not positioned at the jaw center, position errors introduced are:
Add 1% to specified accuracy for measurements made WITHIN jaw marking lines (away from jaw opening)
Add 4% to specified accuracy for measurements made BEYOND jaw marking lines (toward jaws opening)
Test Leads
Amprobe MTL-90B Test Leads with Alligator Clips
High quality test leads with alligator clips
$19.95
$16.96
Accessories
Please consider these optional accessories.
Amprobe RS-232-KIT2 Data Recording Software
Data recording system for Amprobe digital multimeters and clamp-on meter
$59.95
$50.96
Amprobe TPK-59 Thermocouple
Thermocouple for multimeters and clamp-on meters with temperature range from -50 °F to 600 °F
$19.95
$16.96