Amprobe ACD-16 TRMS-PRO Clamp-on Multimeter
1000A datalogging clamp-on multimeter with True-RMS
Availability
Usually ships in 1-2 weeks
Features
- Part number ACD-16 TRMS-PRO
- Manufactured by Amprobe
- True RMS
- AC/DC voltage to 600 V
- AC current to 1000 A
- Resistance, frequency and temperature measurement
- Datalogs up to 5400 points
- Data hold
- Large, easy to read digital dislay
- Accommodates conductors up to 45 mm
- Audible continuity
- Voltage overload protection up to 600 V
Includes FREE
The Amprobe ACD-16 TRMS-PRO 1000A datalogging clamp-on multimeter is the perfect tool to troubleshoot an entire electrical system. The ACD-16 TRMS-PRO provides a full range of measurements, enhanced with datalogging capabilities, to catch what the eye can't see. The efficiency of the meter is doubled when used in conjunction with the optional PC interface kit. True RMS functionality enables accurate readings in noisy electrical environments.
Amprobe ACD-16 TRMS-PRO 1000A datalogging clamp-on multimeters ship complete with:
- Carrying case
- Type-K thermocouple
- Test leads
- Batteries
- User manual
The Amprobe ACD-16 TRMS-PRO 1000A Datalogging Clamp-on Multimeter Specifications
| Function | Range | Accuracy |
|---|---|---|
| AC voltage | ||
| 50 Hz/60 Hz | 600.0 V | 1.0% + 5d |
| 45 Hz ~ 500 Hz | 600.0 V | 1.0% + 5d |
| 500 Hz ~ 3.1 kHz 9 | 600.0 V | 2.5% + 5d |
| CMRR: | >60 dB @ DC to 60 Hz, Rs=1kΩ | |
| Input Impedance: | 2MΩ, 30 pF nominal | |
| True RMS models Crest Factor: | < 2.3:1 at full scale & < 4.6 at half scale | |
| DC voltage | ||
| 600.0 V | 0.5% + 5d | |
| NMRR: | >50 dB @ 50/60 Hz | |
| CMRR: | >120 dB @ DC, 50/60 Hz, Rs=1kΩ | |
| Input Impedance: | 2MΩ, 30 pF nominal | |
| Resistance | ||
| 999.9 Ω | 1.0% + 6d | |
| Open circuit voltage: | 0.4 VDC typical | |
| Audible continuity tester | ||
| Audible threshold: | between 10Ω and 300Ω | |
| Response time: | 250 µs | |
| Frequency | ||
| 5.00 Hz ~ 500.0 Hz | 0.5% + 4d | |
| Sensitivity (Sine RMS) | ||
| 40 A range: > 4A | ||
| 400 A range: > 40A | ||
| 1000 A range: > 400A | ||
| 600 V range: > 30V | ||
| Temperature | ||
| -50°C ~ 300°C | 2.0% + 3°C 1 | |
| -58°F ~ 572°F | 2.0% + 6°F 1 | |
| 1)Add 3°C (or 6°) to specified accuracy@-20°C ~-50°C (or @-4°F ~ -58°F) Type-K thermocouple range & accuracy not included | ||
| AC Current (Clamp-on) | ||
| 50 Hz/60 Hz | 40.00 A, 400.0 A, 1000 A | 1.0% + 5d1)2)3) |
| 45 Hz~500 Hz | 40.00 A, 400.0 A | 2.0% + 5d1)2)3) |
| 1000 A | 2.5% + 5d1)2)3) | |
|
< 2.5:1 at full scale & < 5.0:1 at half scale for 40.00 A & 400.0 A ranges < 1.4:1 at full
scale for 1000 A range 1) Add 8d to specified accuracy while reading is below 10% of range 2) Induced error from adjacent current-carrying conductor: < 0.06 A/A 3) Specified accuracy is for measurements made at the jaw center. When the conductor is not positioned at the jaw center, position errors introduced are: Add 1% to specified accuracy for measurements made WITHIN jaw marking lines (away from jaw opening) Add 4% to specified accuracy for measurements made BEYOND jaw marking lines (toward jaws opening) |
||