TSI Alnor 8375 AccuBalance Air Capture Hood
Multipurpose electronic air balancing instrument for reading air volume flow at diffusers, and grilles
Features
- Part number 8375
- Manufactured by TSI Alnor
- Volume
- Range: 25 to 2,500 ft3/min
- Accuracy: ±3% of reading ±7 ft3/min
- Velocity
- Range (pitot probe): 25 to 8,000 ft/min
- Range (airflow probe): 25 to 5,000 ft/min
- Range (velocity matrix): 25 to 2,500 ft/min
- Best Accuracy: ±3% of reading ±7 ft/min
- Pressure
- Differential: ±15 in. H2O; 150 in. H2O maximum safe operating pressure
- Absolute: 15 to 40 in. Hg
- Best Accuracy: ±2% of reading
- Measures temperature and relative humidity
- Ultra lightweight, ergonomic design
- Detachable digital manometer for use in other applications
- Back pressure compensated
- Multiple hood sizes available
Includes FREE
The TSI Alnor 8375 AccuBalance air capture hood is a multipurpose electronic air balancing instrument for reading air volume flow at diffusers, and grilles. It is ideally suited for commissioning agents, facilities managers, health and safety specialists, test engineers, and test and balance professionals. This ultra light weight, ergonomically designed kit saves time and money while helping to create a healthy and energy efficient environment.
With its ergonomic design, TSI Alnor 8375 AccuBalance air capture hoods are easy for one person to operate. The detachable digital manometer is useful in other applications with pitot, air flor, temperature, velocity matrix or relative humidity probes. With an accuracy of ±3%, the TSI Alnor 8375 measures air velocity over a range of 25 to 8,000 ft/min with a pitot probe. This TSI Alnor air capture hood also measures volume and relative humidity to ±3% accuracy, pressure to ±2% accuracy and temperature to ±0.5°F accuracy.
TSI Alnor 8375 AccuBalance air capture hoods ship complete with base assembly, 2' x 2' hood, 18" pitot probe, two static pressure probes, two 8-foot hoses, battery charger, four NiMH batteries, LogDat1 software, interface cable and wheeled carrying case.
Documents
Specifications
| Temperature Range | Sensor in Base (40 to 140°F (4.4 to 60°C))
Temperature Probe (-40 to 250°F (-40 to 121°C)) Temperature / RH probe (14 to 140°F (-10 to 60°C)) |
|---|---|
| Temperature Resolution | 0.1° |
| Velocity Range | Pitot Probes (25 to 8,000 ft/min (0.125 to 40 m/s))
Airflow Probe (25 to 5,000 ft/min (0.125 to 25 m/s)) |
| Temperature Accuracy | ±0.5 °F (±0.3°C) from 32 to 160°F |
| Operating Temp | 40 to 140°F (4.4 to 60°C) |
| Power Supply | N/A |
| Battery Life | N/A |
| Velocity Resolution | 1 ft/min (0.01 m/s) |
| Velocity Accuracy | ±3% of reading ±7 ft/min (±0.04 m/s) at
velocities >50 ft/min (0.25 m/s) |
| Additional Information | Capable of measuring temperature, velocity, volumetric flow (cfm) and relative humidity |
| Pressure Range | N/A |
| Pressure Accuracy | N/A |
| Output | N/A |
| Time Constant | N/A |
| Relative Humidity Range | 0 to 95% RH temperature/RH probe |
| Relative Humidity Accuracy | ±3% RH |
| Relative Humidity Resolution | 0.1% RH |
| Volumetric Flow Range | 25 to 2,500 ft3/min (42 to 4250 m3/h) capture
hood |
| Volumetric Flow Accuracy | ±3% of reading ±7 ft3/min (±12 m3/h) at flows
>50 ft3/min (>85 m3/h) |
| Volumetric Flow Resolution | 1 ft3/min (1 m3/h) |