TSI Alnor 8371 AccuBalance Air Capture Hood
Measures air volume flowing through registers, diffusers and grilles
Availability
Usually ships in 2-3 weeks
Features
- Part number 8371
- Manufactured by TSI Alnor
- Flow Range: 30 to 2,000 cfm
- Accuracy: ±5 % reading and ±5 cfm
- Operating Temperature: 32 °F to 140 °F
- Battery Life: 40 hours continuous use
- Variable time constant
- K factor function
- Backlit display
Includes FREE
The TSI Alnor 8371 AccuBalance air capture hood measures air volume flowing through registers, diffusers, grilles or the air flow entering exhaust outlets. Weighing just seven and a half pounds, 8371 is easy to carry, lift and use. Simply hold the AccuBalance up to a diffuser or grille and read direct supply or exhaust airflow on the large, backlit digital display.
TSI Alnor 8371 AccuBalance air capture hoods have a range of 30 to 2,000 cfm with an accuracy of ±5% of reading ±5 cfm. The capture hood is temperature-compensated to display a standard flow rate. The instrument can display the measured air flow in four different units: standard cubic feet per minute (SCFM), standard liters per second (Std l/s), standard cubic meters per hour (Std m3/hr), and standard cubic meters per minute (Std m3/min). All readings may also be displayed in actual flow conditions. Variable time constant modes minimize display variations for the 8371 when measuring fluctuating flows. The K factor function provides the 8371 with flexibility for measuring a variety of diffusers.
The TSI Alnor 8371 AccuBalance air capture hood consists of a fabric hood, a molded plastic base which contains an electronic meter, and a flow sensing manifold located within the base. Air flowing through the hood is measured by a hotfilm sensor located in the central hub of the flow sensing manifold. The twenty-four pairs of flow sensing ports in the manifold are strategically located so that the 8371 capture hood provides the highest degree of measurement accuracy, even in non-uniform flow conditions.
TSI Alnor 8371 AccuBalance air capture hoods ship complete with base, battery holder, four C batteries, battery compartment cover, carrying case, operation and service manual, NIST calibration certificate and 2' x 2' (610mm x 610mm) hood and frame hardware.
Documents
Specifications
| Temperature Range | N/A |
|---|---|
| Temperature Resolution | N/A |
| Velocity Range | N/A |
| Temperature Accuracy | N/A |
| Operating Temp | 32 to 140°F (0 to 60°C) |
| Power Supply | 4 C-Size Batteries |
| Battery Life | 40 hr |
| Velocity Resolution | N/A |
| Velocity Accuracy | N/A |
| Additional Information | K factor function enables flexibility for measuring a variety
of diffusers |
| Pressure Range | N/A |
| Pressure Accuracy | N/A |
| Output | N/A |
| Time Constant | N/A |
| Relative Humidity Range | N/A |
| Relative Humidity Accuracy | N/A |
| Relative Humidity Resolution | N/A |
| Volumetric Flow Range | 30 to 2,000 cfm (15 to 1,000 l/s, 50 to 3,500 m3/hr) |
| Volumetric Flow Accuracy | ±5% reading and ±5 cfm |
| Volumetric Flow Resolution | 1 cfm |