TSI Alnor VelociCalc 9525 Air Velocity Meter
Intrinsically safe meter air velocity with 3" retractable probe
Availability
Usually ships in 2-3 weeks
Features
- Part number 9525
- Manufactured by TSI Alnor
- Accurate air velocity measurement suitable for 0 to 2,000 ft/min (0 to 10 m/s)
- Integrated 3” retractable probe attachment
- Large, easy to read display
- Intrinsically safe. UL listed for use in Class I Groups C and D, Class II Groups E, F and G and Class III when used with alkaline batteries.
- NIST-traceable calibration certificate included
- Weighs 0.6 lbs (0.27 kg)
Includes FREE
The TSI Alnor VelociCalc 9525 air velocity meter is an economical, intrinsically safe digital meter typically used for face velocity measurements in fume hoods, spray booths or for IAQ and ventilation system checks. The VelociCalc 9525 utilizes a 3" retractable probe and is UL listed as intrinsically safe for use in hazardous locations for Divisions 1 and 2 in Class I, Groups C and D; Class II, Groups E, F and G; and Class III.
With an accuracy of ±5% of reading or ±5 ft/min (±0.025 m/s), TSI Alnor VelociCalc 9525 air velocity meters measure air velocity over a range from 0 to 2000 ft/min (0 to 10 m/s). Results are shown on the easy to read LCD display. The TSI Alnor VelociCalc includes a certificate of calibration.
The TSI Alnor VelociCalc 9525 air velocity meter ships complete with:
- Hard carrying case
- 4 alkaline batteries
- Operation and service manual
- Calibration certificate
| The TSI Alnor VelociCalc 9525 Air Velocity Meter Specifications: | |
|---|---|
| Air Velocity Range | 0 to 2,000 ft/min (0 to 10 m/s) |
| Accuracy | ±5% of reading or ±5 ft/min (±0.025 m/s), whichever is greater |
| Resolution | 1 ft/min (0.01 m/s) |
| Probe Length | 3.1" |
| Probe Diameter | 0.25" at tip 0.25" at base |
| Power Requirements | 4 AA batteries |
Documents
Specifications
| Temperature Range | N/A |
|---|---|
| Temperature Resolution | N/A |
| Velocity Range | 0 to 10 m/s |
| Temperature Accuracy | N/A |
| Operating Temp | Model 9525 Operating (Probe) 32 to 122°F (0 to 50°C)
Storage -4 to 140°F (-20 to 60°C) |
| Power Supply | 4 AA batteries |
| Battery Life | N/A |
| Velocity Resolution | 0.01 m/s |
| Velocity Accuracy | ±5% of reading or ±5 ft/min (±0.025 m/s),
whichever is greater |
| Additional Information | Intrinsically Safe |
| Pressure Range | N/A |
| Pressure Accuracy | N/A |
| Output | N/A |
| Time Constant | N/A |
| Relative Humidity Range | N/A |
| Relative Humidity Accuracy | N/A |
| Relative Humidity Resolution | N/A |
| Volumetric Flow Range | N/A |
| Volumetric Flow Accuracy | N/A |
| Volumetric Flow Resolution | N/A |