TSI Alnor RVA501 Rotating Vane Anemometer
$825.00
$783.75

Availability

Usually ships in 2-3 weeks

Need Help? Call us M-F 8 AM to 8 PM ET 1-800-884-4967

Features

  • Part number RVA501
  • Manufactured by TSI Alnor
  • Velocity
    • Range: 50 to 6,000 ft/min (0.25 to 30 m/s)
    • Accuracy: ±1.0% of reading ±4 ft/min (±0.02 m/s)
  • Duct Size: 0 to173.6 ft2 (0 to 16 m2)
  • Temperature
    • Range 32 to 140°F (0 to 60°C)
    • Accuracy ±2.0°F (±1.0°C)
    • Resolution 0.1°F (0.1°C)
  • Data Storage: 12,700+ samples and 100 test IDs
  • Logging Interval: From 1 second to 1 hour
  • Time Constant: User selectable

The TSI Alnor RVA501 rotating vane anemometer is a handheld digital anemometer which measures both air velocity and volume flow. It features a 4-inch (100mm) head that automatically averages velocity and volume readings, making the RVA501 an essential tool for measuring unevenly distributed or fluctuating flows through heating and cooling coils, diffusers, grilles, and filters.

The TSI Alnor RVA501 features a measuring range of 50 to 6,000 ft/min (0.25 to 30 m/s) with an accuracy of ±1.0% of reading ±4 ft/min (±0.02 m/s). RVA501 anemometers are effective for duct sizes from 0 to173.6 ft2 (0 to 16 m2). An internal memory stores up to 12,700 samples and 100 test IDs. Other features of the TSI Alnor RVA501 rotating vane anemometer include sweep mode for one overall measurement,the ability to log, store and recall data, PC communications for downloading data and a detachable head for taking readings in tight spaces.

The TSI Alnor RVA501 rotating vane anemometer ships complete with carrying case, alkaline batteries, operation and service manual and NIST calibration certificate, USB cable and LogDat2 downloading software. Optional air cone flow hoods are also available as an accessory to the TSI Alnor RVA501. These hoods will enhance the capability of your RVA501, turning it into an air volume flow balancing tool.

Specifications

Temperature Range32 to 140°F (0 to 60°C)
Temperature Resolution0.1°F (0.1°C)
Velocity Range50 to 6,000 ft/min (0.25 to 30 m/s)
Temperature Accuracy±2.0°F (±1.0°C)
Operating Temp32 to 140°F (0 to 60°C)
Power SupplyFour AA-size batteries or AC adapter
Battery LifeN/A
Velocity Resolution0.01 m/s
Velocity Accuracy±1.0% of reading ±4 ft/min (±0.02 m/s)
Additional InformationMemory Size: 12,700+ samples and 100 test IDs
Pressure RangeN/A
Pressure AccuracyN/A
OutputN/A
Time Constant1 second to 1 hour (user selectable)
Relative Humidity RangeN/A
Relative Humidity AccuracyN/A
Relative Humidity ResolutionN/A
Volumetric Flow Range0 to 210 cfm (0 to 0.1 m3/s)
Volumetric Flow Accuracy±1.0% of reading
Volumetric Flow Resolution0.1 m^3/s
Accessories
Please consider these optional accessories.
TSI Alnor RVA Air Cone Flow Hood Kit
Maximizing the usefulness of rotating vane anemometers by turning them into air volume flow balancing tools
$235.00
$223.25
TSI Alnor Rotating Vane Anemometer Carrying Case
Carrying case designed for use with the TSI Alnor rotating vane anemometers
$125.00
$118.75
TSI Alnor Universal Power Supply
Universal AC adapter designed for use with TSI Alnor instruments
$60.00
$57.00
TSI Alnor RVA Telescopic Rod
36" telescoping rod to increase the reach of TSI Alnor rotating vane anemometers
$150.00
$142.50