Kanomax 6113 & 6114 Multi-Function Thermal Anemometers
Multi-function thermal anemometer with optional built-in printer
Availability
Usually ships in 4-6 business days
Features
- Manufactured by Kanomax
- Air Velocity:
- Range: 20 to 9840 FPM (0.10 to 50.0 m/s)
- Accuracy: ± 3% of reading + 20 FPM (0.1 m/s)
- Air Temperature:
- Range: 32 to 212°F (0 to 100°C)
- Accuracy: ±2.0°F (1.0° C)
- RS-232C Terminal
- Optional Built-in Printer
- Optional Analog Output
- Optional Pressure Module
Includes FREE
The Kanomax 6113/6114 multi-function thermal anemometer simultaneously measures air velocity, temperature, and pressure (optional). Featuring an optional built-in printer and instantaneous storage of up to 100 readings, the Kanomax 6113 makes it simple to keep record of measurements. The Kanomax 6113 is also available without the built-in printer as the Kanomax 6114.
The Kanomax 6113/6114 features probe compatibility and an RS-232C output terminal. Calibration probe compatibility feature allows the utilization of a spare probe, making the meter a very versatile option. The Kanomax 6113/6114 is suitable for measurements inside ducts.
The Kanomax 6113/6114 has a large, easy to read graphic LCD, operation is simple with designated buttons for printing and calculation. The Kanomax 6113 quickly calculates maximum and minimum values, averaging while displaying raw data. The 6113 displays a variety of measuring units (m/s, fpm, Celsius, Fahrenheit, kPa) and can hold a measured value.
The Kanomax 6113/6114 multi-function thermal anemometer ships complete with meter, probe with cable, manual, 6 x 1.5V C cells, extension rod, shoulder strap and printer (6113 only).
Documents
Specifications
| Temperature Range | 32 to 212 °F (0 to 100 °C) |
|---|---|
| Temperature Resolution | 1° |
| Velocity Range | 20 to 9840 fpm (0.10 to 50.0 m/s) |
| Temperature Accuracy | +/-2.0 °F (1.0 °C) |
| Operating Temp | 41 to 104 °F (5 to 40 °C) (Main Body)
32 to 212 °F (0 to 100 °C) (Probe) |
| Power Supply | 6 × 1.5 volt C cells (Mn, alkaline, or Ni-Cd) |
| Battery Life | 10 hours continuous operation |
| Velocity Resolution | 1 fpm (0.1 m/s) |
| Velocity Accuracy | +/-(3% of reading (0.1 m/s)) |
| Additional Information | Quick printing of measurements at site |
| Pressure Range | -5.00 to +5.00kPa (Optional) |
| Pressure Accuracy | +/-(3% of reading +0.01)kPa (Optional) |
| Output | Digital: RS-232C (4800, 9600, 19200, 38400bps) for communication with PC.
Printer Output: Printing calculation results and measurements. Analog (Optional): DC 0 to 1V (1ch. Selected from air velocity, temp. and pressure) |
| Time Constant | N/A |
| Relative Humidity Range | N/A |
| Relative Humidity Accuracy | N/A |
| Relative Humidity Resolution | N/A |
| Volumetric Flow Range | N/A |
| Volumetric Flow Accuracy | N/A |
| Volumetric Flow Resolution | N/A |