Extech AN100/AN200 CFM Thermo-Anemometer
Measures airflow or air velocity, and temperatures to 500°F with infrared thermometer
Promotions
Availability
Select options to see availability
Features
- Manufactured by Extech
- 80 to 5906 ft/min
- 3% velocity accuracy
- 8 area dimensions can be stored
- 20-point average function for air flow
- Large LCD backlit display
- 14 to 140°F (thermistor model AN100)
- -58 to 500°F (infrared model AN200)
- Includes vane sensor with 3.9 ft cable, 9V battery, protective rubber holster and carrying case
Includes FREE
The Extech AN100/AN200 thermo-anemometer offers simultaneous display of ambient temperature and air flow or air velocity. The Extech AN200 thermo-anemometer also includes a built-in non-contact IR thermometer which measures remote surface temperatures between -58 and 500°F with an 8:1 distance to spot ratio and laser pointer. Up to 8 easy-to-set area dimensions can be stored in the internal memory of the Extech AN100/AN200 thermo-anemometer.
The Extech AN100/AN200 thermo-anemometer has a air velocity range from 0.9 to 67.2 mph (or equivalent) and features a 20-point average function for air flow and a super large LCD backlit display. The low friction 2.83" D ball bearing vane wheel on 3.9 ft cable produces a 3% velocity accuracy. Other features of the Extech AN100/AN200 thermo-anemometer includes data hold, min/max readings, and an auto power off. The internal temperature sensor measures ambient temperature from 14 to 140°F.
The Extech AN100/AN200 thermo-anemometer ship complete with vane sensor with 3.9ft cable, 9V battery, protective rubber holster, and carrying case.
Applications of the Extech AN100/AN200 Thermo-Anemometers
- HVAC installation, repair, diagnositics, and optimization
- Fume hood testing, installation, and verification
- Ventiliation system installation, servicing, and analysis
- Environmental wind and temperature testing/analysis
- Boilers rooms
- Ionizer flow output monitoring
- Automobile aerodynamic testing
- Plant/facilities maintenance
Documents
Specifications
| Temperature Range | AN100: 14 to 140˚F (-10 to 60˚C)
AN200 (Non Contact InfraRed): -58 to 500°F (-50 to 260°C) |
|---|---|
| Temperature Resolution | 0.1°F (0.1°C) |
| Velocity Range | 0.40 to 30.00 m/s |
| Temperature Accuracy | AN100: ±6.0°F (3°C)
AN200 (-58 to -4˚F (-50 to -20˚C): ±9.0°F (5°C) (-4 to 500˚F (-20 to 260˚C): ±2% reading or ±2˚F (˚C) whichever is greater |
| Power Supply | 9V battery |
| Battery Life | N/A |
| Velocity Resolution | 0.01 m/s |
| Velocity Accuracy | ±3% m/s |
| Additional Information | 8 area dimensions (ft 2 or cm 2) are stored in the meter's internal memory |
| Pressure Range | N/A |
| Pressure Accuracy | N/A |
| Output | N/A |
| Time Constant | N/A |
| Relative Humidity Range | N/A |
| Relative Humidity Accuracy | N/A |
| Relative Humidity Resolution | N/A |
| Volumetric Flow Range | 0 to 9999 CMM (m3/min) |
| Volumetric Flow Accuracy | N/A |
| Volumetric Flow Resolution | 0.1 |